Usability testing is one of the most significant ways of
performing evaluation. Usability testing is conducted in controlled
environment. There may be cases where it may not be possible to use such
controlled environment.
Mobile usability testing is used in such circumstances. We
can perform this by standard methods, active intervention and co-discovery but
not in the lab environment, it can be tested by laptop having some software any
and necessary hardware.
Let’s take an example from the telecommunication industry.
There are two major categories of telecom companies. One is the vendor that
basically is the developers and inventors of the software and hardware, whereas
Operators are the second category of the industry that purchases telecom
equipment from vendor. Vendors are normally responsible for installation and
configuration of the equipment. The vendors perform the usability testing of
the equipment in front of operators after installation and configuration to
satisfy them.
Optix series equipment can be installed in a cabinet (300 mm
or 600 mm deep)
Or a 19-inch standard cabinet. It can also be installed
against the wall on the floor.
The cabinet consists of the sub racks that consist of the
different cards those are responsible for the routing of the telecom traffic
over the optical and electrical interfaces. After installation of equipment
there is a phase where the inspection of installed equipment is done to check
any faulty physical connections of the power cables & connectors, data
traffic cables, positions of the optical and electrical interface cards,
grounding cables, power box, cabinet is installed properly or not i.e. fixed
well on ground and marking of cabinet in readiness.
The traffic routing cards can handle and process several
users at a time and for every active card there is a back up card that is also
called the protection card. This protection card is placed in the rack. If the
working card gets faulty, the traffic switches on to the other card so that
continuity of the calls didn’t interrupt.
There are different indicators on every card that shows the
status of the card i.e. critical alarm, minor alarm, major alarm, service not configured, working,
power LED indicator, power on/off switch, Received signal loss, input power
high, input power too low etc. If any error occurs during the transmission,
indicators start blinking according to the nature of error. Before commercial
usage the product is testified by generating error to check the alarms working
properly or not, in same way to check the switching of the working card over
the protection is testified by interrupting the traffic on the working card
slot through the software. There are many test conducted during the usability
testing i.e. Power-on Functioning of the Rack, Average Optical Power Transmition,
Actual Received Optical Power, E1 or electrical cable Tributary Test and
Cabling Test, E3/STM-1 Tributary Test and Cabling Test, Power Input Unit
Protection, Fan Rotational Speed Automatically Adjustment network Management
Function Test, Configuration Management Alarm Management, Security Management .To
make the route on the system before use there is a slot for testing and
configuration where laptop can be connected to the system, problems are
rectified through this port.
There is software also installed on the Laptop system to
control and handle the configuration process through laptop. Different menus
and tabs are given on the software to access different functions of the system.
System is configured by making services through the specialized software, during
this process cross connections among optical and electrical interfaces are
done; protection and working cards are configured.
Questions:
By reading the above Scenario, answer the following
Questions:
a) There
are different strategies adopted to prevent any disconnection in the traffic
during failure of any card or cable, mention those.
b) During
usability test, how can a tester check the status of a card without connecting
laptop having software or any testing equipment, i.e. say for example errors on
optical interface card, having service error or the power received low error
that occur when the card is not
receiving signal according to the standard.
c) After
installation and service configuration of the hardware, Testing of the
equipment is done in the presence of engineers & Managers of the customer
company for which system has been installed.
There are different test that are conducted when vendor of the product
handover the equipment to there customers. Mention few test names.
d) Telecom
switches and other systems that basically route and process the telecom traffic
are installed and configured in different steps. First there is a phase called
the survey phase that is done to select the place where equipment has to be
installed physically, than next phase of installation is started where data
cables, power cables and racks are installed, finally the equipment is
configured i.e. services are configured. There are some tools to configure
services in the system, state how a newly installed system is configured.